The MyiQ2, MyiQ, and iQ5 instruments are designed and certified to meet EN-61010 safety standards.ĮN-61010 certified products are safe to use when operated in accordance with the instruction manual. Do not operate the optics module in extreme humidity (that is, greater than 90 percent) or where condensation can short internal electrical circuits or fog optical elements. Do not block the fan vents near the lamp, as this may lead to improper operation or cause physical damage to the detector. To ensure adequate cooling of the system, maintain a clearance of at least 4 inches around the sides of the MyiQ2, MyiQ, or iQ5 optics module. Do not open casing of the optics module when the instrument is in use.įor normal operation, the maximum ambient temperature should not exceed 40☌.

#BIO RAD ICYCLER SKIN#

To prevent skin burns and fire hazards, do not attempt to operate the real-time PCR detection system while the camera case is open. Do not attempt to remove the lamp without powering off the instrument and allowing the system to cool for at least 15 minutes.

bio rad icycler

The camera lamp may get extremely hot during system operation. When you replace the lamp or filters, open only the outer casing of the optics module. Call your local Bio-Rad office for all other optics module and thermal cycler related service. The only user-serviceable parts of the optics module are the lamp and filters. Do not attempt to repair or power on the instrument. If the unit is damaged such that internal components or wires are exposed, contact your local Bio-Rad office immediately. The optical system contains mirrors and lenses that may shatter if the unit is dropped or struck with great force. Handle all components of the real-time PCR detection system with care and with clean, dry hands at all times. Always ensure that you set the module power switch to the off position when you connect or disconnect power cords. Do not use an adaptor to a two-terminal outlet. Phillips is a trademark of Phillips Screw Company Corporation.Īlways connect the MyiQ TM2, MyiQ TM, or iQ TM5 optics module to a three-prong, grounded AC outlet using the AC power cord provided with the system.

bio rad icycler

#BIO RAD ICYCLER WINDOWS#

Excel, Windows, and Windows XP are trademarks of Microsoft Corporation. HEX, TAMRA, TET, and VIC are trademarks of Applera Corp. SYBR and Texas Red are trademarks of Molecular Probes, Inc. to sell reagents containing SYBR ® Green I for use in real-time PCR, for research purposes only.Ĭy is a trademark of GE Healthcare. SYBR is a trademark of Molecular Probes, Inc. patents or their foreign counterparts owned by Eppendorf AG: U.S. Further information on purchasing licenses may be obtained by contacting the Director of Licensing, Applied Biosystems, 850 Lincoln Centre Drive, Foster City, California 94404, USA.īio-Rad’s thermal cyclers and real-time thermal cyclers are covered by one or more of the following U.S. No right is conveyed expressly, by implication or by estoppel under any other patent claim, such as claims to apparatus, reagents, kits, or methods such as 5' nuclease methods. counterparts, owned by Applera Corporation. Purchase of this instrument conveys a limited nontransferable immunity from suit for the purchaser’s own internal research and development and for use in applied fields under one or more of U.S. Thank you very much for your time.Bio-Rad’s real-time thermal cyclers are licensed real-time thermal cyclers under Applera’s United States Patent 6,814,934 B1 for use in research, human in vitro diagnostics, and for all other fields except the field of veterinary diagnostics.

#BIO RAD ICYCLER SERIAL#

I have set the serial port to 57,600 bps, rebooted, etc., but I'm not entirely sure what else I can do to troubleshoot this.Īny help would be immensely appreciated. Set to Bi-Directional, Extended, EPP and/or ECP mode." Reboot system and check BIOS parallel port setting.

#BIO RAD ICYCLER DRIVER#

Running in edit mode only." and "CAMERA FAILURE: Camera port is not bio-directional or (NT only) camera driver IQCAMPP is not loaded. With both the thermal cycler and optical unit turned on and connected via a serial cable to my computer (tested on both Windows XP and Windows 2000), I keep getting the following errors: "Unable to put instrument into remote. However, I am having issues connecting the optical unit to the computer and iCycler IQ Optical System Software. I received what appeared to be a working instrument a couple of months ago, meaning it powers on, heats, etc. This is my first time posting here - I wanted to see if anyone here has had any experience with the BioRad iCycler IQ qPCR thermal cylcer + optical unit.